Colocation Modular Server Cabinets – Server Housing

  • 19″ 1/4 COL Server Cabinet 46U
  • 19″ frame front and rear with HE lettering
  • Basic construction of the cabinet made of stable 12-fold profiled profiles
  • Dimensions (WxHxD): 600x2200x1000mm (46U)
  • Load capacity of the 19″ frames: 1000kg
  • 19″ front, cold-aisle mounting frame with air deflector plate at the top and sides
  • Cold air bulkhead pre-assembled on cabinet side
  • Central grounding point mounted on the cabinet frame
  • Production with coordination according to ÖVE EN62208 + EN61439
  • All RAL colours possible on request

Colocation Server Racks for Server Housing

Server housing offers absolute high availability as an alternative to failure data centers. Especially in countries such as Germany, Austria and Switzerland, server housing is still an issue. It is important to have a modern and reliable data center infrastructure that meets all standards and also offers the highest energy efficiency and availability in the data center.

Colocation server housing – this is your own, separately lockable compartment in a high-quality and modern server cabinet. We install multi-level biometric access control systems and vidio monitoring systems, as well as oversubscription systems, to ensure your security and reliability.

Colocation Data Center Fire Prevention and Early Fire Detection
Fire prevention will be standard in every modern data center in the future. Early fire detection (RAS smoke aspiration systems) and oxygen reductions or argon extinguishing gas systems are already the current “state of the art” in every server room. In the case of colocation data centers, it is mandatory for responsible IT data center operators to use fire prevention systems and to check them regularly.

Colocation Server Cabinets 1/4 for the Data Center

  • Feed-through openings for the cable ducts in the partition shelves must be able to be closed by blank plates
  • can be lined up on all sides
  • Dismountable 3-piece rack floor, interchangeable on bottom plate with mosquito cable entry
  • with 2 side walls per server rack
  • without base and castors
  • Side walls must be recessed and mountable
  • Automatic earthing of all assembled cabinet parts such as rear walls, side walls and floor panels –> test according to DIN EN 60439 1/3
  • Roof sheet with 3 cut-outs for cable entry: 2x laterally, 1x transversely at the rear; Breakouts with interlocking, clip-on brush strips
  • 19″ frame front and rear with HE lettering
  • Surface primed and powder-coated
  • Rack labeling acc. AG
  • 3D planning before production for better visualization

Related Articles

We will be happy to answer your questions and provide technical information .

Login

|

Inhalte für Ihr Land anzeigen?

Wählen Sie ein anderes Land, um Inhalte für Ihren Standort zu sehen:

Login

|

Show content for your country?

Select a different country to see content for your location:

🍪 Accept cookies?

Cookies make it possible to control campaigns and optimize the website. By clicking “Accept”, you agree to the use of all cookies and enter the website. Read more in the privacy policy.

Passwort Vergessen
Forgot Password