UPS systems for server rooms and operations
Uninterruptible power supply is a MUST for all modern operations and IT server rooms. A UPS system reduces the failure rate and supports your operation with reliable power supply. Modern power supply concepts rely on redundant UPS systems with high energy efficiency and long-term lower operating costs.
UPS system as a reliable power supply
UPS systems for industry, plants and data centers
The term “UPS” is primarily about data security and stands for “UPS uninterrupted power supply” and refers to a safety system that protects against disruptions in the energy grid.
In today’s digitalized age, computer and server systems perform a more important task than ever. Without them, modern society would not function in the form it exists now, but still about 50% of all server failures are caused by voltage drops in the power supply. Server operators, who always have to ensure the highest availability for their server system, cannot be responsible for such an outage.
The complete UPS solution from EPS: We take care of it for you
- UPS systems Planning, design and calculation of the load
- On-site inspection and detailed consultation
- If required: solution with an emergency power generator, EBS (External Bypass Switch), ATS (Automatic Transfer Switch) and much more.
- Modern accessories: SNMP card, UPS software, UPS batteries
- Ongoing UPS service: preventive and flexible, UPS power upgrade, replacement of spare parts and much more.
Power outage prevention with a UPS system from EPS
After you have chosen your optimal UPS system, the system is professionally commissioned on site by our own team of EPS technicians.
Our service technicians, trained by the manufacturer’s factory, systematically carry out the commissioning of your UPS. These include:
- Checking the condition of the system (e.g. transport damage),
- Installation of the system,
- Control and functional tests,
- Training of the operating personnel and
- individual advice on maintenance options.
Only through professional commissioning can any fault fields be identified at an early stage and complete UPS operation guaranteed. At the end of the process, you will receive a comprehensive commissioning protocol.
Top Products
We recommend UPS systems from EATON and BORRI, which stand for the highest quality in the field of UPS systems and power supply.
Benefit from our expertise
25
Years of experience
410
Successfully implemented UPS projects
50
Colleague
300+
satisfied customers in the
Domestic and international
We will be happy to support you in the planning and implementation of your UPS project!
Rent
or
Purchase
Flexible financing of your UPS system with EPS
You can rent or lease your UPS system or UPS system flexibly from us. This avoids investment costs and allows you to temporarily limit the use of your UPS system. This is suitable, for example, when relocating the data center or when bridging maintenance times in certain construction phases.
References
After a selection process, Mayr-Melnhof Holz Gaishorn decided in favour of the overall concept of the server room and power supply specialist. The scope of the infrastructure project includes a complete modular, scalable UPS system with UPS systems from the manufacturer Eaton (IT-UPS 93PM Gen2 with 200kVA or 200kW incl. pure lead AGM batteries), an external UPS bypass switch for uninterruptible load switching, temperature and humidity sensors, as well as H2 gas monitoring.
IT UPS and UPS systems: selection, dimensioning and operation
In an emergency, a UPS decides on data loss or continued operation. Here you will find the most important criteria for the selection and modernization of your system.
Seamless power supply thanks to high-availability IT UPS
Voltage fluctuations, frequency deviations and short-term network interruptions are among the most common causes of unexpected IT failures. A professional IT UPS reliably protects your sensitive server and network hardware from such disruptions in the public power grid.
As a buffer storage system, the system takes over the power supply without delay in the event of grid disturbances and at the same time filters out harmful harmonics. This keeps your data intact and significantly extends the service life of the connected components.
We offer you tailor-made UPS concepts that are precisely tailored to the power consumption and the required bridging time of your IT landscape.
Technical dimensioning of modern UPS systems
The selection of the right system typology depends heavily on the individual safety requirements of your company. We rely on proven technologies that are characterized by high efficiency and flexible expansion options. We take the following criteria into account when planning:
- Selection of the appropriate topology (online UPS VFI for maximum protection of critical loads)
- Modular design for easy adjustment of power capacity and redundancy
- Integration of modern battery technologies for long service lives and fast charging times
High-performance UPS systems not only secure individual racks, but can also bridge the complete emergency power supply of entire building sections or data centers until emergency power generators kick in.
Advice and long-term protection for your systems
In order for an uninterruptible power supply to function reliably in an emergency, it must be regularly maintained and checked. We support your IT staff from professional installation to battery management and 24/7 service.
Our technicians carry out capacity tests and replace aged battery cells in good time before a safety risk arises. Rely on clean power quality and avoid expensive system downtimes due to unplanned outages. Contact us for personal advice on your perfect UPS solution.
Uninterruptible power supply requirements
In order to make a technically reliable assessment of which criteria are decisive when selecting an IT UPS for a high-availability data center in the industrial sector, the system topology must be analyzed precisely.
The VFI-SS-111 classification (online continuous converter) is considered the technological standard here, as it completely decouples sensitive hardware from grid fluctuations, frequency deviations and transients. In addition to efficiency in the partial load range (eco-mode efficiency), essential factors are scalability through modular plug-ins and a low mean time to repair (MTTR).
Each technician also pays attention to the implementation of intelligent battery management systems that monitor the state of charge and temperature of the batteries at the cell level and thus ensure their service life.
Systematic inventory and retrofit
If you need or have a comprehensive checklist for the modernization of the UPS systems and air conditioning in an existing, grown data center, a structured audit is essential.
- Recording of real PUE values and thermal hotspots in the server room.
- Dimensioning of the chillers and checking the fluid mechanics in the raised floor.
- Analysis of bypass circuits for maintenance-free switching (maintenance bypass).
The compatibility of new UPS modules with existing emergency power systems (keyword: regenerative resistance) must also be recorded in detail in order to consistently avoid harmonics in the power grid.
Solution architecture and long-term operation
The seamless integration of modern power electronics into existing data center structures ensures the business continuity of business-critical processes. Forward-looking planning takes into account not only the initial installation, but also lifecycle management in order to sustainably reduce the total cost of ownership (TCO).
We design and implement energy-efficient power supply and air conditioning concepts that are precisely tailored to your load profiles. Each system administrator from our support team is at your side for maintenance and proactive monitoring. Get in touch with us to make your IT infrastructure fail-safe and future-oriented through a professional upgrade.
Get our detailed product folders and container floor plans as PDF downloads.