Server room air conditioning for your IT

Why modern data center cooling is more than just an air conditioning system

A server room or data center cooling system does not only have to dissipate heat.

It must keep the thermal conditions for IT stable, avoid hotspots, use energy efficiently and ensure the required availability even in the event of failures, services or maintenance and future expansions.

  • IT Heat Load and Rack Power Density
  • Air ducting and avoidance of bypass/recirculation air
  • Temperature and humidity conditions
  • Redundancy and maintainability
  • Energy and water consumption
  • Refrigerants and legal requirements
  • Monitoring, control and optimisation
  • Extensibility and future IT burdens

Criteria for selecting your suitable IT air conditioning system:

  • Maximum heat load of the data center or server room
  • Packing density per cabinet (maximum heat load per rack)
  • Number of server racks and servers (on-demand performance determination)
  • Temperatures, temperature delta and humidity in the data center
  • Selection of refrigerants to use
  • Scalability, modularity, redundancies
  • Monitoring and control
  • Availability Requirements, Redundancy Requirements
  • Environmental conditions and risks, structural conditions
  • which components (air conditioning technology or refrigeration technology) of the refrigeration system are already in use at the site
  • Profitability Considerations: Investment Costs vs. Operating Costs
  • Consideration of possible subsidies

EPS Air Conditioning

How much cooling capacity does your server room need?

An initial assessment of your cooling requirements in just a few steps. Our experts support you in the individual design of your IT air conditioning system.

Step 1 of 5

Your Server Room Details

Step 2 of 5

IT performance and heat generation

The information helps us to estimate the actual heat load of your IT infrastructure.

Step 3 of 5

Cooling Requirements

Step 4 of 5

Future and project

Floor plan, rack overview, data sheet of the existing air conditioner or technical documentation – max. 5 files, each up to 10 MB (PDF, JPG, PNG, DWG, DXF, XLSX, DOCX, ZIP).

Step 5 of 5

Your contact details

Summary of your information

* Required fields

Thank you very much! Our EPS climate experts will check your information and contact you personally.

IT climate control solutions for your server room

  • Air conditioning above the raised floor: Here, cold air is directed through the raised floor and delivered specifically to the server rack rows. The warm exhaust air is extracted through the back of the server racks and led back to the air conditioning system.
  • Heterogeneous and homogeneous arrangement of server cabinets with cold/hot aisles: Cold and warm air flows are physically separated, which significantly increases the efficiency of cooling.
  • Air conditioning via cold walls
  • Air conditioning with in-row rack cooler (air cooling): Split air conditioners or precision air conditioners are flexible and more cost-effective
  • Air conditioning with in-rack units (air cooling)

  • Free cooling, direct or indirect: this cooling process uses environmental conditions (such as cool outside air or cold water from natural sources) to cool data centers

  • Water cooling: often used for high-performance computing (HPC) systems because it allows for high heat absorption. The waste heat is dissipated via water circuits and can even be reused, for example, for building heating.

  • Air-to-air heat exchangers

  • Hybrid Cooling: Hybrid cooling combines air and water cooling. Due to its high heat capacity, water is used for direct heat dissipation, while air cooling provides additional heat dissipation.

EPS's state-of-the-art data center with UPS system.

FAQs about air conditioning in the server room

What is the ideal temperature for a data center?

For server rooms or data centers, a temperature of 22 to 24 °C is considered a proven guideline. This area is based on ASHRAE recommendations and offers a balanced combination of reliable IT operations and energy efficiency.

However, the optimal temperature depends on several factors – in particular the IT hardware used, the power density of the server racks and the air flow in the room.

We take into account all relevant framework conditions and develop an individually tailored solution for safe, efficient and reliable operation.

A classic split air conditioning system is often not designed for the permanent heat load and 24/7 operation of a server room. The necessary reliability, precise temperature control and targeted air flow are often lacking.

Liquid cooling becomes necessary when conventional air cooling reaches its limits at high heat loads – for example, in high-performance AI applications, HPC systems or particularly densely populated server racks.

The direct cooling of the components allows high amounts of heat to be dissipated efficiently and energy consumption and space requirements to be optimized.

The waste heat from server rooms can often be reused sensibly instead of being released unused into the environment.

It can be used energy-efficiently via heat recovery, for example, for heating buildings, district heating networks, greenhouses or industrial processes.

EPS relies on energy-efficient overall solutions in which cooling and heat recovery should be thought of together, because this turns waste heat into a valuable and sustainable source of energy.

Air conditioning and air conditioning in the data center

EPS accompanies projects throughout the entire life cycle – from analysis and consulting to planning, delivery and installation to maintenance and monitoring.

We recommend cooling systems from our long-standing partners, which stand for the highest quality in the field of IT air conditioning.

Natural Refrigerants in the Data Center - F-Gas-Free Future

Natural and cost-efficient means are increasingly being used in the selection of refrigerants in the server room. Conventional refrigerants that are still used in many air conditioning systems are often hydrofluorocarbons (F-gases). These substances have a high global warming potential (GWP) and contribute significantly to global warming, e.g. in the event of leaks.

The European Union’s F-Gas Regulation aims to greatly reduce these emissions and further promote the use of sustainable alternatives.

Natural refrigerants have very low or global warming potential. Therefore, they are not affected by the F-Gas Regulation.

Natural refrigerants such as propane (R290), CO₂ (R744) and ammonia (R717) are therefore becoming increasingly important in data centers. They are environmentally friendly and often more efficient than synthetic alternatives.

Examples of use in the server room:

  • Propane: Particularly suitable for small to medium-sized systems.
  • CARBON: Used in systems with high pressure requirements.
  • Ammonia: Used for large industrial refrigeration equipment.
Air conditioning for data centers and IT rooms

Refrigeration consumers in the server room

The 4 main refrigeration consumers and their requirements

  • Server
    • are the central components of every data center and thus represent the largest cooling consumers. They generate a large amount of heat. Especially High Performance Computing “HPC” – high-performance servers, can generate waste heat of up to 30kW or even more per server rack

  • Storage
    • Systems such as SANs (Storage Area Networks) or NAS (Network Attached Storage) manage large amounts of data, and while their waste heat is usually lower than servers, it can be significant in modern high-performance storage systems. Above all, they need precise cooling.

  • Network
    • Switches, firewalls or routers are essential for data communication in the data center. Their waste heat is usually generated by processors or power supplies. Their heat load can also be considerable .

  • Other IT equipment in the data centerOther components in the server room are e.g. UPS systems, monitoring systems, IoT devices, etc. UPS systems generate a high amount of waste heat, especially through their batteries and inverters.

Benefit from our expertise

25

Years of experience

78

Successfully implemented climate concepts

50

Colleague

300+

satisfied customers in the
Domestic and international

Request a cooling concept for your IT now and calculate cooling capacity!

Our references for energy-efficient IT cooling solutions

“The data center availability of the new server room infrastructure must be ensured according to current standards. Both the entire power supply and the air conditioning are designed as a multi-path supply with 2N redundancy. A 2(N+1) was produced by modular UPS systems per path to ensure the required availability even during maintenance work,” explains Stefan Austaller, IT division manager at STIWA.

If you have any questions about our services , please do not hesitate to contact us.

Your contact person

Markus
Jährig
Technical Internal Sales
E:

Your contact person

Ing.
Michael
Stern
Sales Export & IT, Authorized Signatory DE
E:
Login

|

Show content for your country?

Select a different country to see content for your location:

We use cookies and similar technologies. Functional cookies are always active in order for this website to function as intended. Statistics and marketing cookies are only set after you have consented. You can use the buttons below to allow or reject each category individually and then click “Save selection” or accept or reject everything with one click. You can change or revoke your selection at any time on the cookie page .

🍪 Accept cookies?

Cookies make it possible to control campaigns and optimize the website. By clicking “Accept”, you agree to the use of all cookies and enter the website. Read more in the privacy policy.

Forgot Password
Forgot Password