Smart Bunker Data Center – IT Cell F120
A wide variety of hazards such as fire, water or liquid leakage, dust, overheating or magnetic interference fields can damage your IT and your data is no longer safe. Short circuits or human error can also cause considerable damage to the IT infrastructure and thus become expensive for the company. Therefore, take care of it in good time with a highly secure safety cell or Server room cell in front. This is a room-in-room solution that provides you with additional protection.
High-security cells as a server room solution
As a data center provider, this is exactly where we come in and want to avoid this risk. We take care of the planning, installation and commissioning of your server room or IT security cell or IT security cell. the high-security data center – as it is a room-in-room solution. We offer an energy-efficient and, above all, individual overall solution for the customer and also install server room infrastructure in an existing server room. In addition, we offer you a solution from a single source: starting with site determination, planning, implementation, installation and professional service. For a fail-safe IT security cell or Smart Bunker, the legal requirements and norms (standards of EN-1047-2 and the values specified therein by the Swiss inspection company SGS) are professionally examined, the customer’s wishes are taken into account and a modern IT server room overall concept is planned.
Fire resistance F120
IT security cell F120 as a room-in-room system. The IT cell complies with the F120 fire resistance specified in the standard and meets the limits for temperature and humidity in accordance with the legal standards. The proof of the fire resistance test was carried out by an independent testing institute. Due to the location and the technical structure of the IT security cell, the high-security data center is reliably protected against temperature increases, increases in relative humidity, penetration of extinguishing water and aggressive fire gases. For the installation, a smooth raw floor covering with a maximum height difference of 2-3% must be ensured. The modular IT security room is self-supporting and free-standing in a “steel cassette construction”. This ensures a later room expansion or a cell move. The scope of delivery includes robust wall, ceiling and floor elements, which are installed and connected to the equipotential bonding system (in accordance with the ÖVE EN standards or VDE EN standards) together with the steel plates and cassettes.
Location requirements for the IT security cell
For the professional and safe installation of an IT security room of the Smart Shelter series, the following conditions and prerequisites must be clarified at the site:
- IT power supply (we are happy to relocate feeds from various transformer stations)
- Sufficient space for the installation of the smart shelter / security cell
- Construction-related restrictions on the installation of the infrastructure
- possible restrictions on the work of fitters
- Maximum load in the IT room per m2
- Plans and floor plans of the entire data center with precise dimensions
We will be happy to support you with a site inspection and help you understand the prerequisites and conditions for a modern IT security cell or IT security cell. security space to record and plan.
IT fire doors in the server room
IT fire doors are available as a single-door system or as double doors with a width of 1100mm and a height of 2200mm. The door hinge can be located on the right or left, depending on your needs. The doors are of course professionally tested according to the latest standards (fire resistance according to system test, smoke gas tightness according to DIN 18095, watertightness according to EN 60529). The security door is equipped with a sliding rail door closer, including an electric safety or motorized lock for easy integration into an access management system
Cable grommets
The cable penetrations installed and installed by us are fireproof, pressurized water and gas-resistant cable bulkheads, which are used for the introduction of data, pipe (cold water) control and supply lines into the IT security cell. The calf bushings consist of a flange frame made of hot-dip galvanized strip steel, a wedge seal with compression units and corresponding modular elements. A frame has space for 36, 48, 96 or more cables with a cable diameter of up to 10.5mm.
Pressure dampers
The overpressure dampers are also fire dampers that are used for installation in the wall of the IT security room. The fire damper is driven by a pneumatic cylinder.
Access systems, UPS systems, emergency power generators and much more.
Many other equipment options such as access systems, UPS systems, emergency power generators or RAS smoke aspiration systems are also planned and installed by us. A modern and efficient IT security cell is more than just a sensible investment. You protect your data and have a long-term investment.