Your modular and
Mobile server room

Datacenter Container – the complete solution from EPS.

Illustration of the interior of the container with different electrical boxes, in blue, light grey, dark grey and pink.
Illustration of a person dressed in dark gray and light gray. Holds a white sheet of paper in his hand and points with his hand to an object on the right.
Illustration of container cover in light brown

Data
Container
too
rentable!

Crane lifts a white container in front of a data center building. In the background you can see the sky, which is blue with clouds.

Your modular and mobile server room

The DC Cont – Data Center Container, is a modular and mobile high-security room. It is set up inside a stable steel container (20f, 40f or NON ISO) by the EPS technician team. The DC CONT can be placed both outdoors and indoors.

The container can also be used for back-up locations or temporary assignments, because the security container, DC Cont, “pulls along” – this guarantees not only the required maximum IT availability but also a high level of investment protection.

The advantages of the DC container

Choose from three container models

DC Container
20f

Mobile standardized steel container
according to ISO 668:1995 for 4 server racks and 12kW IT load

Dimensions:
outside LxWxH: 6000 x 2438 x 2600mm
Inside LxWxH: 5667 x 2152 x 2285mm

DC Container
40f

Mobile standardized steel container
according to ISO 668:1995 with technical room for 4-6 server racks and 30-58kW 2N air conditioning

Dimensions:
outside LxWxH: 12000 x 2438 x 2600mm
Inside LxWxH: 5667 x 2152 x 2285mm

DC Container
NON ISO

is planned according to customer requirements and is flexible in terms of equipment and dimensions

Graphic of container interior with equipment
T-DCC Monitoring

T-DCC Monitoring
and alarm system

IT-DCC NST

IT-DCC NST & NEA PDM + PDM
with ATS or sync unit for a
Automatic switching
on NEA operation

T-DCC UPS

T-DCC UPS PDM Power Distribution Module
+ DCC main distribution board
+ EBS
+ Residual current measurement
+ Energy monitoring according to EN50600
+ Surge protection devices
+ Monitoring of power quality according to DIN EN 50160

IT-DCC UPS Systems

IT-DCC UPS Systems
+ modular and scalable
+ Redundancy level up to 2N

IT RCS-S

IT RCS server rack with adjustable
RCS fins for precise cooling air control
• Reduction of cooling costs
• Increase in packing density
• Avoidance of hot spots

IT-DCC PCS

IT-DCC PCS / PDU ́s
+ Basic or smart

IT air conditioning

IT air conditioning for the DCC
+ possible with free cooling
+ natural refrigerants possible
+ Redundancy level up to 2N

Fire protection:

Technical fire protection:
+ Early fire detection
+ Fire prevention system

IT leak warning system

IT leak warning system for
comprehensive and
Meter-accurate detection

IT-DCC access system

IT-DCC access system and
Burglar alarm system (at the
door)

IT raised floor

IT raised floor in accordance with
EN1081, IEC 61340-4-1 &
DIN EN 12825 Class 5
+ Equipotential bonding system

IT-DCC NEA

IT emergency power generator as emergency power system
+ NEA control for mains-parallel operation
+ NEA control for ATS switching
+ Storage tank

Technical details

The possible applications:

Get our detailed product folders and container floor plans as PDF downloads.

Mockup of the EPS ebook on The Datacenter Container
You are interested in:
By submitting the form, you agree that your details may be used to contact you. Please read our privacy policy .
You are interested in:
By submitting the form, you agree that your details may be used to contact you. Please read our privacy policy .
You are interested in:
By submitting the form, you agree that your details may be used to contact you. Please read our privacy policy .

The equipment of the DC Container

The DC CONT can be individually equipped with state-of-the-art IT infrastructure.
On request, we can take care of the entire process for you: this includes the entire planning, equipment, installation and IT service. You will receive the turnkey version from us, so that you only have to move into your mobile server room.

Two Eaton UPS systems. The systems are black, and there is a display at the front that shows the Eaton logo.

UPS system

The main purpose of a UPS system is to ensure that electricity is available at all times – no matter what. UPS, stands for “Uninterruptible power supply”.

19" RCS Rack cooling via IT raised floor

19″ RCS Rack

With RCS technology, you not only reduce cooling costs, but also increase packing densities, while avoiding “hot spots” and reducing the risk of hot air short circuits.

IT raised floor in the data center

IT raised floor

The raised floor in a data center is the be-all and end-all of a high-availability IT room and an absolute must according to experts.

Transfer and bypass switch

Transfer and bypass switch

Transfer and bypass switches allow switching between power sources and bypassing loads for uninterrupted operation and maintenance.

Other equipment options:

Benefit from our expertise

25

Years of experience

103

successfully implemented
Server Room Projects

50

Colleague

300+

satisfied customers in the
Domestic and international

Together we configure your data center container according to your requirements and wishes!

References

EPS Server Room Container Infrastructure SONNENTOR

SONNENTOR opted for a modern and energy-efficient server room solution in a 20f data center container. This was individually installed and built with the latest IT infrastructure.

PKE implemented a container solution for the on-premise server room to optimize power supply and air conditioning. The existing redundant IT infrastructure was improved by using EPS. Due to effective fire protection in the main building, PKE decided against a geographical relocation and chose the container solution for the external operation of the server room.

Here you can see a data center container with emergency power generator on the company premises of PKE with emergency power generator

If you have any questions about our services , please do not hesitate to contact us.

Peter Reisinger, Vertriebsleiter und Prokurist bei EPS

Your contact person

Peter Reisinger

Sales Manager, Authorized Signatory

EPS-DE-Diana-Engel-Vertrieb

Your contact person

Diana Engel

Sales Manager, Authorized Signatory

Michael Stern, Export Vertrieb IT bei EPS

Your contact person

Ing. Michael Stern

Sales Export IT

Mit Absenden des Formulars erklären Sie sich damit einverstanden, dass Ihre Angaben zur Kontaktaufnahme verwendet werden dürfen. Bitte lesen Sie unserer Datenschutzerklärung einverstanden.
Mit Absenden des Formulars erklären Sie sich damit einverstanden, dass Ihre Angaben zur Kontaktaufnahme verwendet werden dürfen. Bitte lesen Sie unserer Datenschutzerklärung einverstanden.
Mit Absenden des Formulars erklären Sie sich damit einverstanden, dass Ihre Angaben zur Kontaktaufnahme verwendet werden dürfen. Bitte lesen Sie unserer Datenschutzerklärung einverstanden.
Login

|

Inhalte für Ihr Land anzeigen?

Wählen Sie ein anderes Land, um Inhalte für Ihren Standort zu sehen:

Login

|

Show content for your country?

Select a different country to see content for your location:

By submitting the form, you agree that your details may be used to contact you. Please read our privacy policy .
By submitting the form, you agree that your details may be used to contact you. Please read our privacy policy .
By submitting the form, you agree that your details may be used to contact you. Please read our privacy policy .
Virtual 3D tour of emergency power generator

Register here and take a look with us at a data center that has a 1000kVA/800kW PRP (Prime Power) with MTU 16V2000DS1100 diesel engine emergency power supply.

🍪 Accept cookies?

Cookies make it possible to control campaigns and optimize the website. By clicking “Accept”, you agree to the use of all cookies and enter the website. Read more in the privacy policy.

Passwort Vergessen
Forgot Password